Total
70 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-25335 | 2 Google, Samsung | 2 Android, One Ui | 2021-03-11 | 2.5 Low |
Improper lockscreen status check in cocktailbar service in Samsung mobile devices prior to SMR Mar-2021 Release 1 allows unauthenticated users to access hidden notification contents over the lockscreen in specific condition. | ||||
CVE-2021-25348 | 1 Samsung | 1 Internet | 2021-03-05 | 2.4 Low |
Improper permission grant check in Samsung Internet prior to version 13.0.1.60 allows access to files in internal storage without authorized STORAGE permission. | ||||
CVE-2021-0221 | 1 Juniper | 1 Junos | 2021-02-05 | 6.5 Medium |
In an EVPN/VXLAN scenario, if an IRB interface with a virtual gateway address (VGA) is configured on a PE, a traffic loop may occur upon receipt of specific IP multicast traffic. The traffic loop will cause interface traffic to increase abnormally, ultimately leading to a Denial of Service (DoS) in packet processing. The following command could be used to monitor the interface traffic: user@junos> monitor interface traffic Interface Link Input packets (pps) Output packets (pps) et-0/0/1 Up 6492089274364 (70994959) 6492089235319 (70994956) et-0/0/25 Up 343458103 (1) 156844 (0) ae0 Up 9132519197257 (70994959) 9132519139454 (70994956) This issue affects Juniper Networks Junos OS on QFX Series: all versions prior to 17.3R3-S10; 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S5, 18.4R3-S5; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3-S3; 19.2 versions prior to 19.2R1-S5, 19.2R3-S1; 19.3 versions prior to 19.3R2-S5, 19.3R3; 19.4 versions prior to 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R1-S2, 20.2R2. | ||||
CVE-2019-10928 | 1 Siemens | 2 Scalance Sc-600, Scalance Sc-600 Firmware | 2020-10-02 | 6.6 Medium |
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device. | ||||
CVE-2020-2075 | 1 Sick | 60 Clv620, Clv620 Firmware, Clv621 and 57 more | 2020-09-04 | 7.5 High |
Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x – CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH. | ||||
CVE-2020-1644 | 1 Juniper | 2 Junos, Junos Os Evolved | 2020-07-24 | 7.5 High |
On Juniper Networks Junos OS and Junos OS Evolved devices, the receipt of a specific BGP UPDATE packet causes an internal counter to be incremented incorrectly, which over time can lead to the routing protocols process (RPD) crash and restart. This issue affects both IBGP and EBGP multihop deployment in IPv4 or IPv6 network. This issue affects: Juniper Networks Junos OS: 17.2X75 versions prior to 17.2X75-D105.19; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S4; 18.2X75 versions prior to 18.2X75-D13, 18.2X75-D411.1, 18.2X75-D420.18, 18.2X75-D52.3, 18.2X75-D60; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. Juniper Networks Junos OS Evolved: any releases prior to 20.1R2-EVO. This issue does not affect Juniper Networks Junos OS releases prior to 17.3R1. | ||||
CVE-2018-12551 | 1 Eclipse | 1 Mosquitto | 2019-10-26 | N/A |
When Eclipse Mosquitto version 1.0 to 1.5.5 (inclusive) is configured to use a password file for authentication, any malformed data in the password file will be treated as valid. This typically means that the malformed data becomes a username and no password. If this occurs, clients can circumvent authentication and get access to the broker by using the malformed username. In particular, a blank line will be treated as a valid empty username. Other security measures are unaffected. Users who have only used the mosquitto_passwd utility to create and modify their password files are unaffected by this vulnerability. | ||||
CVE-2018-5463 | 1 Lcds | 1 Laquis Scada | 2019-10-09 | N/A |
A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution. | ||||
CVE-2017-16014 | 1 Http-proxy Project | 1 Http-proxy | 2019-10-09 | 7.5 High |
Http-proxy is a proxying library. Because of the way errors are handled in versions before 0.7.0, an attacker that forces an error can crash the server, causing a denial of service. | ||||
CVE-2019-11245 | 1 Kubernetes | 1 Kubernetes | 2019-09-19 | N/A |
In kubelet v1.13.6 and v1.14.2, containers for pods that do not specify an explicit runAsUser attempt to run as uid 0 (root) on container restart, or if the image was previously pulled to the node. If the pod specified mustRunAsNonRoot: true, the kubelet will refuse to start the container as root. If the pod did not specify mustRunAsNonRoot: true, the kubelet will run the container as uid 0. |