Filtered by vendor Siemens Subscriptions
Filtered by product Scalance Xm408-4c Firmware Subscriptions
Total 8 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-46143 1 Siemens 202 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 199 more 2023-12-12 2.7 Low
Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.
CVE-2022-46142 1 Siemens 202 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 199 more 2023-10-10 5.7 Medium
Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords.
CVE-2022-46140 1 Siemens 202 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 199 more 2023-10-10 6.5 Medium
Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system.
CVE-2022-36325 1 Siemens 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more 2023-10-10 4.8 Medium
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
CVE-2022-36324 1 Siemens 168 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 165 more 2023-10-10 7.5 High
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
CVE-2022-36323 1 Siemens 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more 2023-10-10 9.1 Critical
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
CVE-2021-37182 1 Siemens 34 Scalance Xm408-4c, Scalance Xm408-4c Firmware, Scalance Xm408-4c L3 and 31 more 2022-06-27 7.5 High
A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.
CVE-2020-28393 1 Siemens 22 Scalance Xm-400, Scalance Xm-400 Firmware, Scalance Xm408-4c and 19 more 2021-05-21 7.5 High
An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4).