Filtered by vendor Siemens Subscriptions
Filtered by product Logo\!8 Bm Fs-05 Firmware Subscriptions
Total 5 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-36363 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2023-12-12 5.3 Medium
A vulnerability has been identified in LOGO! 12/24RCE (All versions), LOGO! 12/24RCEo (All versions), LOGO! 230RCE (All versions), LOGO! 230RCEo (All versions), LOGO! 24CE (All versions), LOGO! 24CEo (All versions), LOGO! 24RCE (All versions), LOGO! 24RCEo (All versions), SIPLUS LOGO! 12/24RCE (All versions), SIPLUS LOGO! 12/24RCEo (All versions), SIPLUS LOGO! 230RCE (All versions), SIPLUS LOGO! 230RCEo (All versions), SIPLUS LOGO! 24CE (All versions), SIPLUS LOGO! 24CEo (All versions), SIPLUS LOGO! 24RCE (All versions), SIPLUS LOGO! 24RCEo (All versions). Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory.
CVE-2022-36362 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2023-12-12 7.5 High
A vulnerability has been identified in LOGO! 12/24RCE (All versions), LOGO! 12/24RCE (All versions), LOGO! 12/24RCEo (All versions), LOGO! 12/24RCEo (All versions), LOGO! 230RCE (All versions), LOGO! 230RCE (All versions), LOGO! 230RCEo (All versions), LOGO! 230RCEo (All versions), LOGO! 24CE (All versions), LOGO! 24CE (All versions), LOGO! 24CEo (All versions), LOGO! 24CEo (All versions), LOGO! 24RCE (All versions), LOGO! 24RCE (All versions), LOGO! 24RCEo (All versions), LOGO! 24RCEo (All versions), SIPLUS LOGO! 12/24RCE (All versions), SIPLUS LOGO! 12/24RCE (All versions), SIPLUS LOGO! 12/24RCEo (All versions), SIPLUS LOGO! 12/24RCEo (All versions), SIPLUS LOGO! 230RCE (All versions), SIPLUS LOGO! 230RCE (All versions), SIPLUS LOGO! 230RCEo (All versions), SIPLUS LOGO! 230RCEo (All versions), SIPLUS LOGO! 24CE (All versions), SIPLUS LOGO! 24CE (All versions), SIPLUS LOGO! 24CEo (All versions), SIPLUS LOGO! 24CEo (All versions), SIPLUS LOGO! 24RCE (All versions), SIPLUS LOGO! 24RCE (All versions), SIPLUS LOGO! 24RCEo (All versions), SIPLUS LOGO! 24RCEo (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device.
CVE-2022-36361 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2023-12-12 9.8 Critical
A vulnerability has been identified in LOGO! 12/24RCE (All versions), LOGO! 12/24RCEo (All versions), LOGO! 230RCE (All versions), LOGO! 230RCEo (All versions), LOGO! 24CE (All versions), LOGO! 24CEo (All versions), LOGO! 24RCE (All versions), LOGO! 24RCEo (All versions), SIPLUS LOGO! 12/24RCE (All versions), SIPLUS LOGO! 12/24RCEo (All versions), SIPLUS LOGO! 230RCE (All versions), SIPLUS LOGO! 230RCEo (All versions), SIPLUS LOGO! 24CE (All versions), SIPLUS LOGO! 24CEo (All versions), SIPLUS LOGO! 24RCE (All versions), SIPLUS LOGO! 24RCEo (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
CVE-2022-36360 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2023-07-21 7.5 High
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker to manipulate a firmware update and flash it to the device.
CVE-2017-12734 1 Siemens 2 Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware 2022-01-04 7.5 High
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.