A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions < V36.0.156), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21266)
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf | Vendor Advisory |
History
No history.
MITRE Information
Status: PUBLISHED
Assigner: siemens
Published: 2023-09-12T09:32:34.938Z
Updated: 2023-11-14T11:03:43.928Z
Reserved: 2023-08-22T15:41:08.130Z
Link: CVE-2023-41033
JSON object: View
NVD Information
Status : Analyzed
Published: 2023-09-12T10:15:29.783
Modified: 2024-02-16T14:21:36.573
Link: CVE-2023-41033
JSON object: View
Redhat Information
No data.
CWE