Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.
References
Link | Resource |
---|---|
https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md | Third Party Advisory |
History
No history.
MITRE Information
Status: PUBLISHED
Assigner: mitre
Published: 2019-07-03T15:24:45
Updated: 2019-07-03T15:24:45
Reserved: 2018-05-24T00:00:00
Link: CVE-2018-11421
JSON object: View
NVD Information
Status : Analyzed
Published: 2019-07-03T16:15:10.397
Modified: 2020-08-24T17:37:01.140
Link: CVE-2018-11421
JSON object: View
Redhat Information
No data.
CWE