Filtered by CWE-696
Total 8 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-30410 2024-06-18 5.8 Medium
An Incorrect Behavior Order in the routing engine (RE) of Juniper Networks Junos OS on EX4300 Series allows traffic intended to the device to reach the RE instead of being discarded when the discard term is set in loopback (lo0) interface. The intended function is that the lo0 firewall filter takes precedence over the revenue interface firewall filter.  This issue affects only IPv6 firewall filter. This issue only affects the EX4300 switch. No other products or platforms are affected by this vulnerability.  This issue affects Juniper Networks Junos OS: * All versions before 20.4R3-S10, * from 21.2 before 21.2R3-S7, * from 21.4 before 21.4R3-S6.
CVE-2024-35229 2024-05-28 5.3 Medium
ZKsync Era is a layer 2 rollup that uses zero-knowledge proofs to scale Ethereum. Prior to version 1.3.10, there is a very specific pattern `f(a(),b()); check_if_a_executed_last()` in Yul that exposes a bug in evaluation order of Yul function arguments. This vulnerability has been fixed in version 1.3.10. As a workaround, update and redeploy affected contracts.
CVE-2024-30389 2024-05-16 5.8 Medium
An Incorrect Behavior Order vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on EX4300 Series allows an unauthenticated, network-based attacker to cause an integrity impact to networks downstream of the vulnerable device. When an output firewall filter is applied to an interface it doesn't recognize matching packets but permits any traffic. This issue affects Junos OS 21.4 releases from 21.4R1 earlier than 21.4R3-S6. This issue does not affect Junos OS releases earlier than 21.4R1.
CVE-2023-23576 1 Gallagher 1 Command Centre 2024-01-05 4.3 Medium
Incorrect behavior order in the Command Centre Server could allow privileged users to gain physical access to the site for longer than intended after a network outage when competencies are used in the access decision. This issue affects: Gallagher Command Centre: 8.90 prior to vEL8.90.1620 (MR2), 8.80 prior to vEL8.80.1369 (MR3), 8.70 prior to vEL8.70.2375 (MR5), 8.60 prior to vEL8.60.2550 (MR7), all versions of 8.50 and prior.
CVE-2023-44386 1 Vapor 1 Vapor 2023-10-11 5.3 Medium
Vapor is an HTTP web framework for Swift. There is a denial of service vulnerability impacting all users of affected versions of Vapor. The HTTP1 error handler closed connections when HTTP parse errors occur instead of passing them on. The issue is fixed as of Vapor release 4.84.2.
CVE-2023-33224 1 Solarwinds 1 Solarwinds Platform 2023-08-03 7.2 High
The SolarWinds Platform was susceptible to the Incorrect Behavior Order Vulnerability. This vulnerability allows users with administrative access to SolarWinds Web Console to execute arbitrary commands with NETWORK SERVICE privileges.
CVE-2021-22569 2 Google, Oracle 7 Google-protobuf, Protobuf-java, Protobuf-kotlin and 4 more 2023-04-18 5.5 Medium
An issue in protobuf-java allowed the interleaving of com.google.protobuf.UnknownFieldSet fields in such a way that would be processed out of order. A small malicious payload can occupy the parser for several minutes by creating large numbers of short-lived objects that cause frequent, repeated pauses. We recommend upgrading libraries beyond the vulnerable versions.
CVE-2021-31379 1 Juniper 18 Junos, Mx10, Mx10000 and 15 more 2021-10-27 7.5 High
An Incorrect Behavior Order vulnerability in the MAP-E automatic tunneling mechanism of Juniper Networks Junos OS allows an attacker to send certain malformed IPv4 or IPv6 packets to cause a Denial of Service (DoS) to the PFE on the device which is disabled as a result of the processing of these packets. Continued receipt and processing of these malformed IPv4 or IPv6 packets will create a sustained Denial of Service (DoS) condition. This issue only affects MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. An indicator of compromise is the output: FPC ["FPC ID" # e.g. "0"] PFE #{PFE ID # e.g. "1"] : Fabric Disabled Example: FPC 0 PFE #1 : Fabric Disabled when using the command: show chassis fabric fpcs An example of a healthy result of the command use would be: user@device-re1> show chassis fabric fpcs Fabric management FPC state: FPC 0 PFE #0 Plane 0: Plane enabled Plane 1: Plane enabled Plane 2: Plane enabled Plane 3: Plane enabled Plane 4: Plane enabled Plane 5: Plane enabled Plane 6: Plane enabled Plane 7: Plane enabled This issue affects: Juniper Networks Junos OS on MX Series with MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. 17.2 version 17.2R1 and later versions; 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3; 18.3 versions prior to 18.3R2-S4, 18.3R3-S1; 18.4 versions prior to 18.4R1-S8, 18.4R2-S5, 18.4R3; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S5, 19.3R3. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R1.