Filtered by vendor Schneider-electric Subscriptions
Filtered by product Pro-face Blue Subscriptions
Total 8 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-1049 1 Schneider-electric 2 Ecostruxure Operator Terminal Expert, Pro-face Blue 2023-06-22 7.8 High
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI.
CVE-2022-41671 1 Schneider-electric 2 Ecostruxure Operator Terminal Expert, Pro-face Blue 2022-11-08 7.8 High
A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
CVE-2022-41670 1 Schneider-electric 2 Ecostruxure Operator Terminal Expert, Pro-face Blue 2022-11-08 7.8 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
CVE-2022-41669 1 Schneider-electric 2 Ecostruxure Operator Terminal Expert, Pro-face Blue 2022-11-08 7.8 High
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
CVE-2022-41668 1 Schneider-electric 2 Ecostruxure Operator Terminal Expert, Pro-face Blue 2022-11-05 7.8 High
A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
CVE-2022-41667 1 Schneider-electric 2 Ecostruxure Operator Terminal Expert, Pro-face Blue 2022-11-05 7.8 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
CVE-2022-41666 1 Schneider-electric 2 Ecostruxure Operator Terminal Expert, Pro-face Blue 2022-11-05 7.8 High
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
CVE-2020-28221 1 Schneider-electric 42 Ecostruxure Operator Terminal Expert, Gp-4104g, Gp-4104w and 39 more 2021-02-12 9.8 Critical