Filtered by vendor Mitsubishi Subscriptions
Filtered by product Ae-200a Firmware Subscriptions
Total 3 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-24296 1 Mitsubishi 40 Ae-200a, Ae-200a Firmware, Ae-200e and 37 more 2022-06-17 7.5 High
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.
CVE-2021-20593 1 Mitsubishi 38 Ae-200a, Ae-200a Firmware, Ae-200e and 35 more 2021-08-05 7.1 High
Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior) and Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) allows a remote authenticated attacker to impersonate administrators to disclose configuration information of the air conditioning system and tamper information (e.g. operation information and configuration of air conditioning system) by exploiting this vulnerability.
CVE-2021-20595 1 Mitsubishi 38 Ae-200a, Ae-200a Firmware, Ae-200e and 35 more 2021-08-04 8.2 High
Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets.