Filtered by vendor Tenda
Subscriptions
Total
741 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-40839 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADF3C' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADF3C" function to execute commands. | ||||
CVE-2023-40840 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "fromGetWirelessRepeat." | ||||
CVE-2023-40841 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "add_white_node," | ||||
CVE-2023-40842 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | 9.8 Critical |
Tengda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "R7WebsSecurityHandler." | ||||
CVE-2023-40843 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "sub_73004." | ||||
CVE-2023-40845 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks. | ||||
CVE-2023-40847 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "initIpAddrInfo." In the function, it reads in a user-provided parameter, and the variable is passed to the function without any length check. | ||||
CVE-2023-40848 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "sub_7D858." | ||||
CVE-2023-40837 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-01 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADD50' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADD50" function to execute commands. | ||||
CVE-2023-41561 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2023-09-01 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. | ||||
CVE-2023-40838 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-01 | 9.8 Critical |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability. | ||||
CVE-2023-41560 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-09-01 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. | ||||
CVE-2023-41562 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2023-09-01 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. | ||||
CVE-2023-41563 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2023-09-01 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. | ||||
CVE-2023-41559 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2023-09-01 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. | ||||
CVE-2023-41552 | 1 Tenda | 4 Ac7, Ac7 Firmware, Ac9 and 1 more | 2023-08-31 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. | ||||
CVE-2023-41553 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2023-08-31 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. | ||||
CVE-2023-41557 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac7 and 1 more | 2023-08-31 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. | ||||
CVE-2023-41555 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2023-08-31 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet. | ||||
CVE-2023-41554 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-31 | 9.8 Critical |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. |