Filtered by vendor Tenda Subscriptions
Total 741 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-40839 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-07 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADF3C' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADF3C" function to execute commands.
CVE-2023-40840 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-07 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "fromGetWirelessRepeat."
CVE-2023-40841 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-07 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "add_white_node,"
CVE-2023-40842 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-07 9.8 Critical
Tengda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "R7WebsSecurityHandler."
CVE-2023-40843 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-07 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "sub_73004."
CVE-2023-40845 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-07 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks.
CVE-2023-40847 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-07 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "initIpAddrInfo." In the function, it reads in a user-provided parameter, and the variable is passed to the function without any length check.
CVE-2023-40848 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-07 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "sub_7D858."
CVE-2023-40837 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-01 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADD50' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADD50" function to execute commands.
CVE-2023-41561 1 Tenda 4 Ac5, Ac5 Firmware, Ac9 and 1 more 2023-09-01 9.8 Critical
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
CVE-2023-40838 1 Tenda 2 Ac6, Ac6 Firmware 2023-09-01 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability.
CVE-2023-41560 1 Tenda 2 Ac9, Ac9 Firmware 2023-09-01 9.8 Critical
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.
CVE-2023-41562 1 Tenda 6 Ac5, Ac5 Firmware, Ac7 and 3 more 2023-09-01 9.8 Critical
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
CVE-2023-41563 1 Tenda 4 Ac5, Ac5 Firmware, Ac9 and 1 more 2023-09-01 9.8 Critical
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.
CVE-2023-41559 1 Tenda 6 Ac5, Ac5 Firmware, Ac7 and 3 more 2023-09-01 9.8 Critical
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
CVE-2023-41552 1 Tenda 4 Ac7, Ac7 Firmware, Ac9 and 1 more 2023-08-31 9.8 Critical
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
CVE-2023-41553 1 Tenda 4 Ac5, Ac5 Firmware, Ac9 and 1 more 2023-08-31 9.8 Critical
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.
CVE-2023-41557 1 Tenda 4 Ac5, Ac5 Firmware, Ac7 and 1 more 2023-08-31 9.8 Critical
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.
CVE-2023-41555 1 Tenda 2 Ac7, Ac7 Firmware 2023-08-31 9.8 Critical
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet.
CVE-2023-41554 1 Tenda 2 Ac9, Ac9 Firmware 2023-08-31 9.8 Critical
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.