CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-42972 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2023-02-08 | 7.8 High |
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
CVE-2022-42973 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2023-02-08 | 7.8 High |
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
CVE-2022-32526 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32525 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32522 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32524 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32527 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32529 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-32523 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
CVE-2022-2329 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
CVE-2021-22786 | 1 Schneider-electric | 82 Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware, Modicon M340 Bmxp342000 and 79 more | 2023-02-08 | 7.5 High |
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions) | ||||
CVE-2022-32513 | 1 Schneider-electric | 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more | 2023-02-08 | 9.8 Critical |
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) | ||||
CVE-2022-32514 | 1 Schneider-electric | 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more | 2023-02-08 | 9.8 Critical |
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) | ||||
CVE-2022-24324 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-02-08 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
CVE-2023-22611 | 1 Schneider-electric | 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 | 2023-02-07 | 7.5 High |
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022) | ||||
CVE-2022-32519 | 1 Schneider-electric | 1 Data Center Expert | 2023-02-07 | 9.8 Critical |
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0) | ||||
CVE-2022-32518 | 1 Schneider-electric | 1 Data Center Expert | 2023-02-07 | 9.8 Critical |
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0) | ||||
CVE-2022-32520 | 1 Schneider-electric | 1 Data Center Expert | 2023-02-07 | 9.8 Critical |
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0) | ||||
CVE-2022-32517 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2023-02-07 | 6.5 Medium |
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conextâ„¢ ComBox (All Versions) | ||||
CVE-2022-32515 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2023-02-07 | 9.8 Critical |
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conextâ„¢ ComBox (All Versions) |