CVE-2023-25620 1 Schneider-electric 16 140cpu65, 140cpu65 Firmware, Bmeh58s and 13 more 2023-05-12 6.5 Medium
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user.
CVE-2023-25619 1 Schneider-electric 14 Bmeh58s, Bmeh58s Firmware, Bmep58s and 11 more 2023-05-12 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol.
CVE-2023-1548 1 Schneider-electric 1 Ecostruxure Control Expert 2023-05-12 5.5 Medium
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
CVE-2023-28003 1 Schneider-electric 1 Ecostruxure Power Monitoring Expert 2023-05-01 8.8 High
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate user has signed out of their account.
CVE-2023-25556 1 Schneider-electric 14 Merten Instabus Tastermodul 1fach System M, Merten Instabus Tastermodul 1fach System M Firmware, Merten Instabus Tastermodul 2fach System M and 11 more 2023-04-28 8.8 High
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.
CVE-2023-29411 2 Microsoft, Schneider-electric 7 Windows 10, Windows 11, Windows Server 2016 and 4 more 2023-04-28 9.8 Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
CVE-2023-29413 2 Microsoft, Schneider-electric 7 Windows 10, Windows 11, Windows Server 2016 and 4 more 2023-04-28 7.5 High
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
CVE-2023-28004 1 Schneider-electric 2 Powerlogic Hdpm6000, Powerlogic Hdpm6000 Firmware 2023-04-28 9.8 Critical
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.
CVE-2023-29410 1 Schneider-electric 6 Conext Gateway, Conext Gateway Firmware, Insightfacility and 3 more 2023-04-28 8.8 High
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.
CVE-2023-25547 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 8.8 High
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2022-43378 1 Schneider-electric 10 Netbotz 355, Netbotz 355 Firmware, Netbotz 450 and 7 more 2023-04-27 6.5 Medium
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause the user to be tricked into performing unintended actions when external address frames are not properly restricted. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior)
CVE-2022-34755 1 Schneider-electric 1 Easergy Builder Installer 2023-04-27 6.7 Medium
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior)
CVE-2023-25548 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 6.5 Medium
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25549 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 9.8 Critical
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25550 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 9.8 Critical
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25552 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 8.1 High
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25551 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 6.1 Medium
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25553 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 6.1 Medium
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25554 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 7.8 High
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25555 1 Schneider-electric 1 Struxureware Data Center Expert 2023-04-27 8.1 High
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)