CVE-2018-7831 1 Schneider-electric 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more 2020-08-24 N/A
An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a password change on the web server.
CVE-2018-7816 1 Schneider-electric 118 D6220, D6220 Firmware, D6220l and 115 more 2020-08-24 N/A
A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file.
CVE-2018-7814 1 Schneider-electric 1 Guicon 2020-08-24 N/A
A Stack-based Buffer Overflow (CWE-121) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) which could cause remote code to be executed when parsing a GD1 file
CVE-2018-7779 1 Schneider-electric 6 Homelynk, Homelynk Firmware, Spacelynk and 3 more 2020-08-24 N/A
In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access.
CVE-2018-7803 1 Schneider-electric 1 Triconex Tristation Emulator 2020-08-24 N/A
A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant.
CVE-2020-7520 1 Schneider-electric 1 Software Update Utility 2020-07-28 4.7 Medium
A CWE-601: URL Redirection to Untrusted Site ('Open Redirect') vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim's machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker's possession. A man-in-the-middle attack is then used to complete the exploit.
CVE-2020-7517 1 Schneider-electric 1 Easergy Builder 2020-07-27 5.5 Medium
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to read user credentials.
CVE-2020-7514 1 Schneider-electric 1 Easergy Builder 2020-07-27 7.8 High
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker access to the authorization credentials for a device and gain full access.
CVE-2020-7518 1 Schneider-electric 1 Easergy Builder 2020-07-27 7.5 High
A CWE-20: Improper input validation vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to modify project configuration files.
CVE-2020-7519 1 Schneider-electric 1 Easergy Builder 2020-07-27 7.5 High
A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account.
CVE-2012-0931 1 Schneider-electric 1 Modicon Quantum Plc 2020-07-23 9.8 Critical
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.
CVE-2012-0929 1 Schneider-electric 1 Modicon Quantum Plc 2020-07-23 7.5 High
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server.
CVE-2012-0930 1 Schneider-electric 1 Modicon Quantum Plc 2020-07-23 6.1 Medium
Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2020-7492 1 Schneider-electric 1 Gp-pro Ex Firmware 2020-06-24 6.5 Medium
A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded.
CVE-2020-7497 1 Schneider-electric 1 Ecostruxure Operator Terminal Expert 2020-06-19 9.8 Critical
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts.
CVE-2020-7495 1 Schneider-electric 1 Ecostruxure Operator Terminal Expert 2020-06-19 5.5 Medium
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access outside of expected path folder when opening the project file.
CVE-2020-7494 1 Schneider-electric 1 Ecostruxure Operator Terminal Expert 2020-06-19 7.8 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
CVE-2020-7512 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2020-06-19 9.8 Critical
A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to exploit the component.
CVE-2020-7509 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2020-06-17 7.2 High
A CWE-269: Improper privilege management (write) vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to elevate their privileges and delete files.
CVE-2020-7508 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2020-06-17 9.8 Critical