Filtered by vendor Schneider-electric
Subscriptions
Total
732 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2015-0999 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2021-05-14 | N/A |
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file. | ||||
CVE-2019-6848 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2021-04-19 | 8.6 High |
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module. | ||||
CVE-2019-6838 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2021-04-16 | 6.5 Medium |
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to delete a critical file. | ||||
CVE-2019-6836 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2021-04-16 | 7.5 High |
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file. | ||||
CVE-2021-22710 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-18 | 7.8 High |
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2021-22711 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-17 | 7.8 High |
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data. | ||||
CVE-2021-22709 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-17 | 7.8 High |
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2021-22712 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-17 | 7.8 High |
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address. | ||||
CVE-2020-7553 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-15 | 7.8 High |
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-28221 | 1 Schneider-electric | 42 Ecostruxure Operator Terminal Expert, Gp-4104g, Gp-4104w and 39 more | 2021-02-12 | 9.8 Critical |
A CWE-20: Improper Input Validation vulnerability exists in EcoStruxureâ„¢ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI. | ||||
CVE-2020-7550 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 7.8 High |
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-7554 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 7.8 High |
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-7556 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 7.8 High |
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-7557 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 7.8 High |
A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-7558 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 7.8 High |
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-7555 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-01-30 | 7.8 High |
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-28219 | 1 Schneider-electric | 2 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2020-12-16 | 7.8 High |
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX. | ||||
CVE-2020-28218 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 6.5 Medium |
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to trick a user into initiating an unintended action. | ||||
CVE-2020-28217 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 7.5 High |
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. | ||||
CVE-2020-28215 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 9.8 Critical |
A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently. |