CVE-2021-22697 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2022-01-31 | 7.8 High |
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | ||||
CVE-2020-10626 | 2 Fazecast, Schneider-electric | 2 Jserialcomm, Ecostruxure It Gateway | 2022-01-31 | 7.8 High |
In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code. | ||||
CVE-2020-7552 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2022-01-01 | 7.8 High |
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-7551 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2022-01-01 | 7.8 High |
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2020-7515 | 1 Schneider-electric | 1 Easergy Builder | 2021-12-10 | 7.8 High |
A CWE-321: Use of hard-coded cryptographic key stored in cleartext vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker to decrypt a password. | ||||
CVE-2020-7516 | 1 Schneider-electric | 1 Easergy Builder | 2021-12-10 | 7.8 High |
A CWE-316: Cleartext Storage of Sensitive Information in Memory vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker access to login credentials. | ||||
CVE-2021-22720 | 1 Schneider-electric | 1 C-bus Toolkit | 2021-11-30 | 7.2 High |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project. | ||||
CVE-2020-7484 | 2 Microsoft, Schneider-electric | 4 Windows 7, Windows Nt, Windows Xp and 1 more | 2021-11-10 | 7.5 High |
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former 'password' feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions. | ||||
CVE-2020-7483 | 2 Microsoft, Schneider-electric | 4 Windows 7, Windows Nt, Windows Xp and 1 more | 2021-11-08 | 7.5 High |
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause certain data to be visible on the network when the 'password' feature is enabled. This vulnerability was discovered in and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. The 'password' feature is an additional optional check performed by TS1131 that it is connected to a specific controller. This data is sent as clear text and is visible on the network. This feature is not present in TriStation 1131 versions v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions. | ||||
CVE-2019-6854 | 1 Schneider-electric | 1 Clearscada | 2021-11-03 | 7.8 High |
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017. | ||||
CVE-2021-22769 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2021-09-20 | 4.3 Medium |
A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted. | ||||
CVE-2021-22704 | 1 Schneider-electric | 10 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 7 more | 2021-09-20 | 9.1 Critical |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP. | ||||
CVE-2019-6839 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2021-09-14 | 8.8 High |
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file. | ||||
CVE-2021-22793 | 1 Schneider-electric | 5 Accusine Pcs\+, Accusine Pcsn, Accusine Pcsn Active Harmonic Filter Firmware and 2 more | 2021-09-13 | 7.2 High |
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol. | ||||
CVE-2021-22790 | 1 Schneider-electric | 49 Modicon M340 Bmxp341000, Modicon M340 Bmxp342010, Modicon M340 Bmxp342020 and 46 more | 2021-09-13 | 6.5 Medium |
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). | ||||
CVE-2021-22791 | 1 Schneider-electric | 49 Modicon M340 Bmxp341000, Modicon M340 Bmxp342010, Modicon M340 Bmxp342020 and 46 more | 2021-09-13 | 6.5 Medium |
A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). | ||||
CVE-2021-22789 | 1 Schneider-electric | 49 Modicon M340 Bmxp341000, Modicon M340 Bmxp342010, Modicon M340 Bmxp342020 and 46 more | 2021-09-13 | 6.5 Medium |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). | ||||
CVE-2021-22792 | 1 Schneider-electric | 49 Modicon M340 Bmxp341000, Modicon M340 Bmxp342010, Modicon M340 Bmxp342020 and 46 more | 2021-09-13 | 7.5 High |
A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). | ||||
CVE-2021-22775 | 1 Schneider-electric | 1 Gp-pro Ex | 2021-09-10 | 7.8 High |
A CWE-427: Uncontrolled Search Path Element vulnerability exists in GP-Pro EX,V4.09.250 and prior, that could cause local code execution with elevated privileges when installing the software. | ||||
CVE-2018-3639 | 12 Arm, Canonical, Debian and 9 more | 321 Cortex-a, Ubuntu Linux, Debian Linux and 318 more | 2021-08-13 | 5.5 Medium |
Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4. |