Filtered by vendor Mitsubishielectric Subscriptions
Total 144 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-4562 1 Mitsubishielectric 380 Fx3g-14 Mr\/ds, Fx3g-14 Mr\/ds Firmware, Fx3g-14 Mr\/es and 377 more 2023-10-23 9.1 Critical
Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages.
CVE-2021-20588 1 Mitsubishielectric 41 C Controller Module Setting And Monitoring Tool, Cpu Module Logging Configuration Tool, Cw Configurator and 38 more 2023-10-18 9.8 Critical
Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
CVE-2023-4088 1 Mitsubishielectric 1 Gx Works3 2023-09-28 7.8 High
Incorrect Default Permissions vulnerability due to incomplete fix to address CVE-2020-14496 in Mitsubishi Electric Corporation FA engineering software products allows a malicious local attacker to execute a malicious code, which could result in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition. However, if the mitigated version described in the advisory for CVE-2020-14496 is used and installed in the default installation folder, this vulnerability does not affect the products.
CVE-2023-1618 1 Mitsubishielectric 2 Melsec Ws0-geth00200, Melsec Ws0-geth00200 Firmware 2023-08-23 8.6 High
Active Debug Code vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Serial number 2310 **** and prior allows a remote unauthenticated attacker to bypass authentication and illegally log into the affected module by connecting to it via telnet which is hidden function and is enabled by default when shipped from the factory. As a result, a remote attacker with unauthorized login can reset the module, and if certain conditions are met, he/she can disclose or tamper with the module's configuration or rewrite the firmware.
CVE-2023-0525 1 Mitsubishielectric 14 Gs21, Gs21 Firmware, Gs25 and 11 more 2023-08-10 7.5 High
Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled.
CVE-2023-3373 1 Mitsubishielectric 4 Gs21, Gs21 Firmware, Gt21 and 1 more 2023-08-10 9.1 Critical
Predictable Exact Value from Previous Values vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT21 model versions 01.49.000 and prior and GOT SIMPLE Series GS21 model versions 01.49.000 and prior allows a remote unauthenticated attacker to hijack data connections (session hijacking) or prevent legitimate users from establishing data connections (to cause DoS condition) by guessing the listening port of the data connection on FTP server and connecting to it.
CVE-2022-25155 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2023-08-08 8.1 High
Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GN11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GN11-EIP all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by replaying an eavesdropped password hash.
CVE-2022-25156 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2023-08-08 8.1 High
Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by using a password reversed from a previously eavesdropped password hash.
CVE-2022-25157 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2023-08-08 9.1 Critical
Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GF11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GP21(S)-SX all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to disclose or tamper with the information in the product by using an eavesdropped password hash.
CVE-2021-20612 1 Mitsubishielectric 6 Fx3u-enet, Fx3u-enet-l, Fx3u-enet-l Firmware and 3 more 2023-08-08 7.5 High
Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.
CVE-2022-33323 1 Mitsubishielectric 102 Rh-12fh55, Rh-12fh55 Firmware, Rh-12fh70 and 99 more 2023-07-21 7.5 High
Active Debug Code vulnerability in robot controller of Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series allows a remote unauthenticated attacker to gain unauthorized access by authentication bypass through an unauthorized telnet login. As for the affected model names, controller types and firmware versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
CVE-2023-2846 1 Mitsubishielectric 300 Fx3g-14mr\/ds, Fx3g-14mr\/ds Firmware, Fx3g-14mr\/es and 297 more 2023-07-10 9.1 Critical
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series main modules allows a remote unauthenticated attacker to cancel the password/keyword setting and login to the affected products by sending specially crafted packets.
CVE-2022-29830 1 Mitsubishielectric 1 Gx Works3 2023-06-29 9.1 Critical
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
CVE-2022-29828 1 Mitsubishielectric 1 Gx Works3 2023-06-29 7.5 High
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally.
CVE-2022-29827 1 Mitsubishielectric 1 Gx Works3 2023-06-29 7.5 High
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally.
CVE-2022-25164 1 Mitsubishielectric 2 Gx Works3, Mx Opc Ua Module Configurator-r 2023-06-29 7.5 High
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.
CVE-2022-29831 1 Mitsubishielectric 1 Gx Works3 2023-06-29 7.5 High
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
CVE-2022-29826 1 Mitsubishielectric 1 Gx Works3 2023-06-27 7.5 High
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
CVE-2023-0457 1 Mitsubishielectric 76 Fx5-enet, Fx5-enet\/ip, Fx5-enet\/ip Firmware and 73 more 2023-06-21 7.5 High
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server.
CVE-2023-2060 1 Mitsubishielectric 8 Fx5-enet\/ip, Fx5-enet\/ip Firmware, Rj71eip91 and 5 more 2023-06-16 7.5 High
Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing.