Filtered by vendor Crestron Subscriptions
Total 40 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2019-3925 1 Crestron 4 Am-100, Am-100 Firmware, Am-101 and 1 more 2020-10-16 9.8 Critical
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
CVE-2019-3937 1 Crestron 4 Am-100, Am-100 Firmware, Am-101 and 1 more 2020-10-16 7.8 High
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data.
CVE-2019-3934 1 Crestron 4 Am-100, Am-100 Firmware, Am-101 and 1 more 2020-10-16 5.3 Medium
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code.
CVE-2019-3933 1 Crestron 4 Am-100, Am-100 Firmware, Am-101 and 1 more 2020-10-16 5.3 Medium
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.
CVE-2019-3910 1 Crestron 2 Airmedia Am-100, Airmedia Am-100 Firmware 2020-08-24 N/A
Crestron AM-100 before firmware version 1.6.0.2 contains an authentication bypass in the web interface's return.cgi script. Unauthenticated remote users can use the bypass to access some administrator functionality such as configuring update sources and rebooting the device.
CVE-2018-5553 1 Crestron 6 Dge-100, Dge-100 Firmware, Dm-dge-200-c and 3 more 2019-10-09 N/A
The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.
CVE-2018-10630 1 Crestron 15 Mc3, Mc3 Firmware, Tsw-1060-b-s and 12 more 2019-10-09 N/A
For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001, The devices are shipped with authentication disabled, and there is no indication to users that they need to take steps to enable it. When compromised, the access to the CTP console is left open.
CVE-2017-16709 1 Crestron 4 Airmedia Am-100, Airmedia Am-100 Firmware, Airmedia Am-101 and 1 more 2019-10-03 N/A
Crestron Airmedia AM-100 devices with firmware before 1.6.0 and AM-101 devices with firmware before 2.7.0 allows remote authenticated administrators to execute arbitrary code via unspecified vectors.
CVE-2018-13341 1 Crestron 15 Mc3, Mc3 Firmware, Tsw-1060-b-s and 12 more 2019-10-03 N/A
Crestron TSW-X60 all versions prior to 2.001.0037.001 and MC3 all versions prior to 1.502.0047.00, The passwords for special sudo accounts may be calculated using information accessible to those with regular user privileges. Attackers could decipher these passwords, which may allow them to execute hidden API calls and escape the CTP console sandbox environment with elevated privileges.
CVE-2018-11229 1 Crestron 8 Crestron Toolbox Protocol Firmware, Dmc-str, Tsw-1060 and 5 more 2019-05-13 N/A
Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP).
CVE-2018-11228 1 Crestron 8 Crestron Toolbox Protocol Firmware, Dmc-str, Tsw-1060 and 5 more 2019-05-02 N/A
Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via a Bash shell service in Crestron Toolbox Protocol (CTP).
CVE-2017-16710 1 Crestron 4 Airmedia Am-100, Airmedia Am-100 Firmware, Airmedia Am-101 and 1 more 2018-09-05 N/A
Cross-site scripting (XSS) vulnerability in Crestron Airmedia AM-100 devices with firmware before 1.6.0 and AM-101 devices with firmware before 2.7.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2016-5639 1 Crestron 2 Airmedia Am-100, Airmedia Am-100 Firmware 2017-09-03 N/A
Directory traversal vulnerability in cgi-bin/login.cgi on Crestron AirMedia AM-100 devices with firmware before 1.4.0.13 allows remote attackers to read arbitrary files via a .. (dot dot) in the src parameter.
CVE-2016-5671 1 Crestron 2 Dm-txrx-100-str, Dm-txrx-100-str Firmware 2016-08-16 N/A
Multiple cross-site request forgery (CSRF) vulnerabilities on Crestron Electronics DM-TXRX-100-STR devices with firmware through 1.3039.00040 allow remote attackers to hijack the authentication of arbitrary users.
CVE-2016-5667 1 Crestron 2 Dm-txrx-100-str, Dm-txrx-100-str Firmware 2016-08-15 N/A
Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 allow remote attackers to bypass authentication via a direct request to a page other than index.html.
CVE-2016-5640 1 Crestron 2 Airmedia Am-100, Airmedia Am-100 Firmware 2016-08-15 N/A
Directory traversal vulnerability in cgi-bin/rftest.cgi on Crestron AirMedia AM-100 devices with firmware before 1.4.0.13 allows remote attackers to execute arbitrary commands via a .. (dot dot) in the ATE_COMMAND parameter.
CVE-2016-5669 1 Crestron 2 Dm-txrx-100-str, Dm-txrx-100-str Firmware 2016-08-15 N/A
Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 use a hardcoded 0xb9eed4d955a59eb3 X.509 certificate from an OpenSSL Test Certification Authority, which makes it easier for remote attackers to conduct man-in-the-middle attacks against HTTPS sessions by leveraging the certificate's trust relationship.
CVE-2016-5666 1 Crestron 2 Dm-txrx-100-str, Dm-txrx-100-str Firmware 2016-08-15 N/A
Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 rely on the client to perform authentication, which allows remote attackers to obtain access by setting the value of objresp.authenabled to 1.
CVE-2016-5668 1 Crestron 2 Dm-txrx-100-str, Dm-txrx-100-str Firmware 2016-08-15 N/A
Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 allow remote attackers to bypass authentication and change settings via a JSON API call.
CVE-2016-5670 1 Crestron 2 Dm-txrx-100-str, Dm-txrx-100-str Firmware 2016-08-15 N/A
Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 have a hardcoded password of admin for the admin account, which makes it easier for remote attackers to obtain access via the web management interface.