Filtered by vendor Tenda
Subscriptions
Total
741 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-37712 | 1 Tenda | 6 Ac1206, Ac1206 Firmware, F1202 and 3 more | 2023-07-13 | 9.8 Critical |
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function. | ||||
CVE-2023-37711 | 1 Tenda | 4 Ac10, Ac10 Firmware, Ac1206 and 1 more | 2023-07-13 | 9.8 Critical |
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function. | ||||
CVE-2023-37710 | 1 Tenda | 4 Ac10, Ac10 Firmware, Ac1206 and 1 more | 2023-07-13 | 9.8 Critical |
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. | ||||
CVE-2023-37706 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2023-07-13 | 9.8 Critical |
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function. | ||||
CVE-2023-37707 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2023-07-13 | 9.8 Critical |
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. | ||||
CVE-2023-37705 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2023-07-13 | 9.8 Critical |
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function. | ||||
CVE-2023-37704 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2023-07-13 | 9.8 Critical |
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | ||||
CVE-2023-37703 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2023-07-13 | 9.8 Critical |
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | ||||
CVE-2023-37702 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2023-07-13 | 9.8 Critical |
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function. | ||||
CVE-2023-37701 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2023-07-13 | 9.8 Critical |
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. | ||||
CVE-2023-37700 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2023-07-13 | 9.8 Critical |
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | ||||
CVE-2023-37144 | 2 Tenda, Tendacn | 2 Ac10, Ac10 Firmware | 2023-07-12 | 9.8 Critical |
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. | ||||
CVE-2022-40010 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-07-03 | 5.4 Medium |
Tenda AC6 AC1200 Smart Dual-Band WiFi Router 15.03.06.50_multi was discovered to contain a cross-site scripting (XSS) vulnerability via the deviceId parameter in the Parental Control module. | ||||
CVE-2023-33530 | 1 Tenda | 2 G103, G103 Firmware | 2023-06-15 | 8.8 High |
There is a command injection vulnerability in the Tenda G103 Gigabit GPON Terminal with firmware version V1.0.0.5. If an attacker gains web management privileges, they can inject commands gaining shell privileges. | ||||
CVE-2023-33675 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | 9.8 Critical |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function. | ||||
CVE-2023-33673 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | 9.8 Critical |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | ||||
CVE-2023-33672 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | 7.5 High |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. | ||||
CVE-2023-33671 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | 9.8 Critical |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function. | ||||
CVE-2023-33670 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | 9.8 Critical |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function. | ||||
CVE-2023-33669 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | 9.8 Critical |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function. |