CVE-2023-6198 | 2024-06-27 | 9.3 Critical | ||
Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device. | ||||
CVE-2024-39374 | 2024-06-27 | N/A | ||
TELSAT marKoni FM Transmitters are vulnerable to an attacker exploiting a hidden admin account that can be accessed through the use of hard-coded credentials. | ||||
CVE-2023-6448 | 1 Unitronics | 33 Samba 3.5, Samba 3.5 Firmware, Samba 4.3 and 30 more | 2024-06-26 | 9.8 Critical |
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system. | ||||
CVE-2024-5460 | 2024-06-26 | 8.1 High | ||
A vulnerability in the default configuration of the Simple Network Management Protocol (SNMP) feature of Brocade Fabric OS versions before v9.0.0 could allow an authenticated, remote attacker to read data from an affected device via SNMP. The vulnerability is due to hard-coded, default community string in the configuration file for the SNMP daemon. An attacker could exploit this vulnerability by using the static community string in SNMP version 1 queries to an affected device. | ||||
CVE-2024-36496 | 2024-06-26 | N/A | ||
The configuration file is encrypted with a static key derived from a static five-character password which allows an attacker to decrypt this file. The application hashes this five-character password with the outdated and broken MD5 algorithm (no salt) and uses the first five bytes as the key for RC4. The configuration file is then encrypted with these parameters. | ||||
CVE-2024-6045 | 2024-06-24 | 8.8 High | ||
Certain models of D-Link wireless routers contain an undisclosed factory testing backdoor. Unauthenticated attackers on the local area network can force the device to enable Telnet service by accessing a specific URL and can log in by using the administrator credentials obtained from analyzing the firmware. | ||||
CVE-2024-29963 | 2024-06-18 | 1.9 Low | ||
Brocade SANnav OVA before v2.3.1, and v2.3.0a, contain hardcoded TLS keys used by Docker. Note: Brocade SANnav doesn't have access to remote Docker registries. | ||||
CVE-2024-27160 | 2024-06-17 | 6.2 Medium | ||
All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL. | ||||
CVE-2024-27161 | 2024-06-17 | 6.2 Medium | ||
all the Toshiba printers have programs containing a hardcoded key used to encrypt files. An attacker can decrypt the encrypted files using the hardcoded key. Insecure algorithm is used for the encryption. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL. | ||||
CVE-2024-27159 | 2024-06-17 | 6.2 Medium | ||
All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL. | ||||
CVE-2024-27170 | 2024-06-17 | 7.4 High | ||
It was observed that all the Toshiba printers contain credentials used for WebDAV access in the readable file. Then, it is possible to get a full access with WebDAV to the printer. As for the affected products/models/versions, see the reference URL. | ||||
CVE-2024-27168 | 2024-06-17 | 7.1 High | ||
It appears that some hardcoded keys are used for authentication to internal API. Knowing these private keys may allow attackers to bypass authentication and reach administrative interfaces. As for the affected products/models/versions, see the reference URL. | ||||
CVE-2024-38281 | 2024-06-14 | N/A | ||
An attacker can access the maintenance console using hard coded credentials for a hidden wireless network on the device. | ||||
CVE-2024-0865 | 2024-06-13 | 7.8 High | ||
CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege escalation when logged in as a non-administrative user. | ||||
CVE-2024-1228 | 1 Eurosoft | 1 Przychodnia | 2024-06-12 | 9.8 Critical |
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed). | ||||
CVE-2024-3699 | 1 Dreryk | 1 Gabinet | 2024-06-12 | 9.8 Critical |
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0. | ||||
CVE-2024-3700 | 1 Estomed | 1 Simple Care | 2024-06-12 | 9.8 Critical |
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Simple Care software installations. This issue affects Estomed Sp. z o.o. Simple Care software in all versions. The software is no longer supported. | ||||
CVE-2024-29063 | 2024-06-11 | 7.3 High | ||
Azure AI Search Information Disclosure Vulnerability | ||||
CVE-2018-11682 | 1 Lutron | 6 Homeworks Qs, Homeworks Qs Firmware, Radiora 2 and 3 more | 2024-06-10 | N/A |
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine | ||||
CVE-2024-32740 | 2024-06-06 | 9.8 Critical | ||
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network. |